Rules of Thumb
   
Piping
  1. Flanges and fittings are rated for 150, 300, 600, 900, 1,500 or 2,500 psig.
  2. Line velocties and pressure drops, with line diameter, D, given in in.; Liquid pump discharge (5 + D/3) ft/s, 2.0 psi/100 ft; liquid pump suction (1/3 + D/6) ft/s, 0.4 psi/100 ft; steam or gas 20D ft/s 0.5 psi/100 ft.
  3. Control valves require at least a 10 psi drop for good control.
  4. Screwed fittings are used only on sizes 1.5 inch; smaller, flanged or welded fittings are used otherwise.